About This Trial
The objective of this prospective, multicenter, randomized, controlled clinical trial is to demonstrate the superiority of the VBX Device for primary patency when compared to bare metal stenting in complex iliac occlusive disease.
Who May Be Eligible (Plain English)
Who May Qualify:
- Age ≥ 18 years at time of willing to sign a consent form signature
- willing to sign a consent form Form (ICF) is signed by the subject
- Subject can comply with protocol requirements, including follow-up
- Patient has symptomatic claudication, rest pain, or minor tissue loss (Rutherford Category 2-5)
- Patient has de novo or restenotic lesion(s) found in the common and/or external iliac artery(ies)
- Patient has: Unilateral or bilateral single or multiple lesions (\>50% stenosis or chronic total occlusion) each between 4 and 11 cm in length
- Patient has a target vessel diameter visually estimated to be approximately between 5 mm and 13 mm
- Patient has a sufficient (\<50% stenotic) common femoral artery and at least one sufficient (\<50% stenotic) femoral artery (deep or superficial).
- Patient has at least one sufficient (\<50% stenotic) infrapopliteal run-off vessel.
Who Should NOT Join This Trial:
- Life expectancy \<1 year
- Patient is pregnant at time of willing to sign a consent form.
- Patient has a known allergy to stent or stent graft components (including nitinol, stainless steel, or heparin).
- Patient has severe chronic renal insufficiency (serum creatinine level \> 2.5mg/dL) and not undergoing hemodialysis.
- Patient has evidence of a systemic infection.
- Patient has a known intolerance to antithrombotic medications that prevent compliance with study or control device Instructions for Use.
- Patient has had vascular catheterization of the lower extremities within 30 days of randomization (excluding diagnostic angiograms for the study procedure).
- Patient has previous stenting in the iliac arteries.
- Patient has previous surgical bypass in the target limb.
- Patient is currently participating in another investigative clinical study unless received written approval by the sponsor.
- Patient has a lesion requiring drug-coated balloon angioplasty, atherectomy, lithotripsy, or any ablative device to facilitate stent delivery.
...See full criteria on ClinicalTrials.gov
Always talk to your doctor about whether this trial is right for you.
Original Eligibility Criteria
View original clinical language
Inclusion Criteria:
* Age ≥ 18 years at time of informed consent signature
* Informed Consent Form (ICF) is signed by the subject
* Subject can comply with protocol requirements, including follow-up
* Patient has symptomatic claudication, rest pain, or minor tissue loss (Rutherford Category 2-5)
* Patient has de novo or restenotic lesion(s) found in the common and/or external iliac artery(ies)
* Patient has: Unilateral or bilateral single or multiple lesions (\>50% stenosis or chronic total occlusion) each between 4 and 11 cm in length
* Patient has a target vessel diameter visually estimated to be approximately between 5 mm and 13 mm
* Patient has a sufficient (\<50% stenotic) common femoral artery and at least one sufficient (\<50% stenotic) femoral artery (deep or superficial).
* Patient has at least one sufficient (\<50% stenotic) infrapopliteal run-off vessel.
Exclusion Criteria:
* Life expectancy \<1 year
* Patient is pregnant at time of informed consent.
* Patient has a known allergy to stent or stent graft components (including nitinol, stainless steel, or heparin).
* Patient has severe chronic renal insufficiency (serum creatinine level \> 2.5mg/dL) and not undergoing hemodialysis.
* Patient has evidence of a systemic infection.
* Patient has a known intolerance to antithrombotic medications that prevent compliance with study or control device Instructions for Use.
* Patient has had vascular catheterization of the lower extremities within 30 days of randomization (excluding diagnostic angiograms for the study procedure).
* Patient has previous stenting in the iliac arteries.
* Patient has previous surgical bypass in the target limb.
* Patient is currently participating in another investigative clinical study unless received written approval by the sponsor.
* Patient has a lesion requiring drug-coated balloon angioplasty, atherectomy, lithotripsy, or any ablative device to facilitate stent delivery.
* Patient has an abdominal aortic artery lesion or aneurysm.
* Patient has a lesion that requires stent placement within 2 cm of the inguinal ligament.
* Patient has isolated common iliac artery stenosis that can be treated with a single device (i.e., common iliac artery stenosis that does not require kissing stents or extend into the external iliac artery).
* Patient has outflow disease that requires concomitant interventions (i.e. common femoral endarterectomy or femoral / tibial revascularization).
Treatments Being Tested
DEVICE
Stenting of the Common and/or External Iliac Arteries with the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis
Treatment of target lesions in the common and/or external iliac arteries by stenting with the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis.
DEVICE
Stenting of the Common and/or External Iliac Arteries with Bare Metal Stent
Treatment of target lesions in the common and/or external iliac arteries by stenting with a commercially available bare metal stent that is approved for treatment of the disease.
Locations (7)
North Suburban Medical Center
Denver, Colorado, United States
Radiology and Imaging Specialists of Lakeland
Lakeland, Florida, United States
University of Pennsylvania
Philadelphia, Pennsylvania, United States
The University of Texas Southwestern Medical Center
Dallas, Texas, United States
Krankenhaus der Barmherzigen Brüder
Regensburg, Germany
Rijnstate Hospital
Arnhem, Netherlands
Auckland City Hospital
Auckland, New Zealand